DIMENSIONS
240cm | 600cm | 14.4 m²
SUMMARY
- 130mm Galvanized Frame
- 50 mm High Insulated Sandwich Panel
- Roof & Ground Insulation
- 500 kg / m² burden capacity
- 262 cm Height
*THE FIRST TWO PHOTOS SHOW THE EXACT MODEL. REST OF THE PHOTOS ARE GENERAL. FOR DESIRED ROOM/WINDOW TYPES CHECK THE PRODUCT CODES AND THE FIRST TWO PHOTOS.
GENERAL INFO
SILVER CONTAINER TECHNICAL SPECIFICATIONS
Standard Sizes of Containers are 4000x264 and 240x54
SNOW BURDEN: 50 kg/m² - Exterior Wall Heat Conductivity U Value: 0.35 (W/m²K)
WINDSPEED: 60 km/h - Roof Heat Conductivity U Value: 0.30 (W/m²K)
FLOOR CHASSIS CAPACITY: 500 kg/m²
BOTTOM AND TOP CHASSIS: 2 mm Special reshaped Steel by Beam Bender ST37
CORNER COLUMNS: 80*80*2 mm Tubular Steel
SANDWICH PANEL: 50 mm Sandwich Panel (Ral 9002 Color Sheet Metal + 45 mm 14-16 Density EPS + Ral 9002 Sheet Metal) + Water Barrier Mattress + Trapez Metal Sheet 0.40 mm
INTERNAL WALL SYSTEM: 50 mm Sandwich Panel (Ral 9002 Color Sheet Metal + 45 mm 14-16 Density EPS + Ral 9002 Sheet Metal)
EXTERNAL WALL SYSTEM: 50 mm Sandwich Panel (Ral 9002 Color Sheet Metal + 45 mm 14-16 Density EPS + Ral 9002 Sheet Metal)
HEIGHT: 2640 mm (The Overall Size of Under Carrier Eyebolt)
FRAME: 2 mm Special Reshaped Steel by Beam Bender + 40x80x1.5 mm C shaped galvanized profiles (13 Pieces for 240x600 models) (37.5 cm Periodicity)
BOTTOM INSULATION: 60 mm 14-16 Density EPS + 0.45 mm metal sheet
COVERING: 14 mm Fibre-cement Profiled Sheet (Betopan as Brand)
FLOOR COVERING: 1-1.5mm pvc Floor Covering
EXTERNAL DOORS: Size (Clear-Cut Door Space): 900*2000 mm - Door: Press Panel Metal Door - Heat and Sound Insulation Material: 40 mm POLYURETHANE (40 kg/m³)
INTERNAL DOORS: Size (Clear-Cut Door Space): 800*2000 mm and 900*2000 mm - Door: American Press Panel Door - Knob Lock
WC DOORS: Size (Clear-Cut Door Space): 700*2000 mm - Door: American Press Panel Door
NORMAL WINDOWS: 97*100 cm Sized PVC (Single Opening One Sash) ( Krauss Branded, White Color )
WC and Shower Volumes: 350*350 - 350*450 mm Vent-Hole
NORMAL WINDOWS: 4+16+4 Double Glazing
EXTERIOR PAINT COLOR: Ral 9002
COVERING MATERIALS and CORNERS: RAL 7015
WIRE: 240 Volt Capacity ( CE-TSE Certified, 3*2.5, 3*1.5 ve 2*1.5 mm² 1034 NVV )
SOCKETS and BUTTONS: CE-TSE Certified Surface Mounted Switches and Sockets
SOCKET WIRES: NVV 3*2.5 mm2 (TSE-ISO-CE)
ILLUMINATION WIRES: NVV 3*1.5 mm2 (TSE-ISO-CE)
BRAKER and FUSE-BOX: CE-TSE Certified 10,16,25 and 32 Amp Brakers with 4 - 6 - 8 - 12 Covered Overfill Fuse
LIGHTING FIXTURES: Normal Places: Glop Lamp - Wet Places: Glop Lamp - Above External Door: Glop Lamp
NOTE:
*There is no residual current device.
*Each wall socket is 240 W
*Different usages (stove, air conditioner, household electricity appliances ) should be
*Each air conditioner should be fed with another braker
PIPE (CLEAN WATER): Φ20 PPRC Pipe
PIPE (WASTE WATER): Waste Water Pipes: Φ 50 and Φ 100 PVC - Lavabo: 28*45 cm Wall Type (CE-TSE Certified ) - Lavabo Tap: Wall Mounted Taps ( CE-TSE Certified ) - Toilet: Plastic Reservoir, Backside Output Flush Toilet - WC Stone: Lavatory Pan - Shower Tray: 80*80 Acrylic - Shower Faucet: Mix Bath Faucet - Bidet Nozzle: Wall-Mounted Taps - Kitchen Counter: 45*85 Melamine Coated Chipboard with Chrome Sink - Main Line Connection : Waste and Clean Water Pipe Major Connections - Employer
GUARANTEE CONDITIONS: Fermendi Prefab Construction Technologies products have 1 year warranty for manufacturing and assembly faults. For any kind of fault situation, the fault should be identified clearly and the documents, which are wanted by Fermendi Prefab like 30 cm, 2m and 10 m distance photos of fault, must be given to company to fix the mistake. The problems, which happened during transport or occur because of usage, are not under warranty.